|
User manual for Dorrough 40-AE Analog Loudness Meter 40-AE
- Manufacturer: Dorrough
- Basic description and contents of package
- Product classification: Pro Audio - General Accessories - Metering
- Safety instructions
- Startup and operation of the metering
- Tips for setting up your Dorrough
- Settings and expert assistance
- Contact Dorrough service
- Troubleshooting
- Warranty information
- Price: 450 USD
|
We recommend checking out our discussion threads on the Dorrough 40-AE Analog Loudness Meter 40-AE,
which address similar problems with connecting and setting up Metering Dorrough.
|
User manual for the Dorrough 40-AE Analog Loudness Meter 40-AE
The user manual for the Dorrough 40-AE Analog Loudness Meter 40-AE provides
necessary instructions for the proper use of the product Pro Audio - General Accessories - Metering.
The Dorrough 40-AE Analog Loudness Meter +43dB is a loudness meter with a large display scale allowing 43dB of headroom in 1dB steps and XLR left and right connectors. The headroom scale is identical to the AES/EBU Digital Standard.
|
If you own a Dorrough metering and have a user manual in electronic form,
you can upload it to this website using the link on the right side of the screen.
You can upload and download the manual for the Dorrough 40-AE Analog Loudness Meter 40-AE in the following formats:
- *.pdf, *.doc, *.txt, *.jpg - Other formats are unfortunately not supported.
|
Additional parameters of the Dorrough 40-AE Analog Loudness Meter 40-AE:
Input Impedance | 20k Ohm balanced, 10k Ohm single-ended, +/- 2% | Common Mode Rejection Ratio | 80 dB at 60 Hz, 60 dB at 20 kHz (balanced mode) | Input Sensitivity | -10 dB for full-scale display | Maximum Input Level | +24 dB before clipping | Signal Path Bandwidth | 10 Hz - 25 kHz, +/- .25 dB | Signal Path Distortion | Less than 1% THD at 1 kHz, +24 dB input | Sum Error | Less than 0.1 dB at 1 kHz | Difference Error | Less than 0.1 dB at 1 kHz | Display Resolution | Less than 0.1 dB at 1 kHz | Step Size Error | +/- 0.25 dB | Absolute Error | Full Scale -39 dBu: +/- 0.25 dB model A,B,C | Drift | +/- 0.25 dB | Average Time Constant | 600 mS, +/- 6% | Peak Acquisition Period | 10 uS, to full-scale, sine input 25kHz | Peak Attack Period | Virtually Instantaneous | Peak Decay Period | 180 mS, from full-scale to all LEDs off (models A, B, C) | Display Update Rate | Approximately 10 mS | Display Duty Cycle | Display Time, AVERAGE, PEAK HOLD - 75% Display Time, PEAK - 100% | Power Supply Input Range | 117/237 VAC RMS, -20% to +10%, 50-60 Hz | Calibration Controls | None Needed | User Controls | Left/Right input sensitivity Option DIP Switch A) Peak Auto [ON] B) Difference Mode [ON/OFF] C) Over Level Alarm [ENABLE] D) Under Level Alarm [ENABLE] E) Auto ARMP | User Port | DB-9 Connector A) Alarm relay closure contacts 1 form C, 1A, 30V AC or DC B) Mode control switch (user supplied) C) PEAK function switch (user supplied) | Dimensions (WxDxH) | 8.5 x 6.5 x 2.8" (in) (3.3 x 2.6 x 1.1cm) | Weight | Not Specified by Manufacturer | Package Weight | 5.0 lb | Box Dimensions (LxWxH) | 11.5 x 9.0 x 5.0" | |
The user manual for the Dorrough 40-AE Analog Loudness Meter 40-AE can be downloaded in .pdf
format if it did not come with your new metering, although the seller is
required to supply one. It is also quite common that customers throw out
the user manual with the box, or put the CD away somewhere and then can’t find it.
That’s why we and other Dorrough users keep a unique electronic library
for Dorrough meterings,
where you can use our link to download the user manual for the Dorrough 40-AE Analog Loudness Meter 40-AE.
The user manual lists all of the functions of the Dorrough 40-AE Analog Loudness Meter 40-AE,
all the basic and advanced features and tells you how to use the metering.
The manual also provides troubleshooting for common problems. Even greater
detail is provided by the service manual, which is not typically shipped with the product,
but which can often be downloaded from Dorrough service.
If you want to help expand our database, you can upload a link to this website
to download a user manual or service manual, ideally in .pdf format. These pages
are created by you – users of the Dorrough 40-AE Analog Loudness Meter 40-AE. User manuals are also
available on the Dorrough website under Pro Audio - General Accessories - Metering.
Question and answer discussion forum concerning user instructions and resolving problems with the Dorrough 40-AE Analog Loudness Meter 40-AE
Post new comment to Dorrough 40-AE Analog Loudness Meter 40-AE
Subject: 40-AE | Date: 08.09.2023 03:31:58 | Author: Mark W Persons | I have a 40-AE on the bench that reads full scale with no audio input. The problem is somewhere around U1, but I need a schematic to trace it down. The power supplies are clean. It appears there are just two voltage regulators, as opposed to three on other models. | Reply |
Post new comment/question/response regarding the Dorrough 40-AE Analog Loudness Meter 40-AE
|
|
|
|
|